You are not logged in.
Experiment: CLAS12 RG-K, 2022
Spokespersons: Daniel S. Carman
Measurement comment: Coordinate system:
(x,y,z), z along virtual photon direction, y normal to electron scattering plane, x=y x z
Q2 bin: [0.9:0.3] GeV^2
cos(θKc.m.) bin: [0.0:0.5]
Publication:
Quantity measured: P′z,
z projection of beam-recoil transferred polarization P′ in (x,y,z) system
Beam: e, polarization: none
Target: p (Z=1, A=1), polarization: none
Final state: K+ Σ0, polarization: polarized
Q2 : | 0.3 — 0.9 GeV2 | |
---|---|---|
W : | 1.6 — 2.4 GeV | |
Ebeam : | 6.535 GeV |
Observable quantity measured (Y axis): P′z,
Parameter (X axis): W, GeV |
Click here to get data in text file, delimited with tabs.
Measured data:
W,
GeV |
P′z | Data errors | Systematic errors |
---|---|---|---|
1.64 | 0 | 0 | 0 |
1.72 | 0.7583 | 0.3462 | 0.12583 |
1.8 | 0.05987 | 0.12722 | 0.07585 |
1.88 | 0.06559 | 0.08516 | 0.04612 |
1.96 | -0.00271 | 0.08634 | 0.05005 |
2.04 | -0.16622 | 0.09555 | 0.05982 |
2.12 | -0.09108 | 0.10204 | 0.06189 |
2.2 | -0.15929 | 0.11198 | 0.05842 |
2.28 | -0.14343 | 0.12655 | 0.05408 |
2.36 | -0.23698 | 0.14883 | 0.05217 |