You are not logged in.
Experiment: CLAS12 RG-K, 2022
Spokespersons: Daniel S. Carman
Measurement comment: P′x vs. Q2 (integrated over W, cos(θKc.m.))
Coordinate system:
(x,y,z), z along virtual photon direction, y normal to electron scattering plane, x=y x z
Publication:
Quantity measured: P′x,
x projection of beam-recoil transferred polarization P′ in (x,y,z) system
Beam: e, polarization: none
Target: p (Z=1, A=1), polarization: none
Final state: K+ Λ, polarization: polarized
Q2 : | 0.3 — 3.5 GeV2 | |
---|---|---|
W : | 1.6 — 2.4 GeV | |
Ebeam : | 6.535 GeV |
Observable quantity measured (Y axis): P′x,
Parameter (X axis): Q2, GeV2 |
Click here to get data in text file, delimited with tabs.
Measured data:
Q2,
GeV2 |
P′x | Data errors | Systematic errors |
---|---|---|---|
0.35 | -0.01177 | 0.00935 | 0.0211 |
0.45 | 0.00654 | 0.00912 | 0.02005 |
0.55 | -0.0333 | 0.00994 | 0.01928 |
0.65 | 0.00116 | 0.01076 | 0.01848 |
0.75 | -0.00146 | 0.0117 | 0.01813 |
0.85 | -0.03759 | 0.01268 | 0.01767 |
0.95 | 0.00622 | 0.01373 | 0.01762 |
1.05 | -0.00244 | 0.01484 | 0.01704 |
1.15 | -0.02589 | 0.01605 | 0.01707 |
1.25 | 0.01131 | 0.0173 | 0.01677 |
1.35 | -0.00797 | 0.01893 | 0.0167 |
1.45 | -0.03439 | 0.02055 | 0.01691 |
1.6 | 0.00248 | 0.01665 | 0.01688 |
1.8 | 0.0148 | 0.01973 | 0.01714 |
2 | 0.04614 | 0.02313 | 0.01716 |
2.2 | -0.0264 | 0.02721 | 0.01708 |
2.4 | 0.08014 | 0.03182 | 0.01723 |
2.65 | -0.01682 | 0.03126 | 0.01702 |
2.95 | -0.07199 | 0.03641 | 0.01648 |
3.3 | -0.07325 | 0.03989 | 0.01605 |