Measurement E179M17
| Experiment: | SIDIS Dihadron Beam Spin Asymmetry | |
|---|---|---|
| Year: | 2020 | |
| Spokespersons: | C. Dilks, T. Hayward, A. Vossen | |
| Reaction: | ep → π π + X | |
| Polarization: | beam (longitudinal) | |
| Quantity: | ALUsin (2φh−2φR) | |
| Q2: | 1.0 — 10.6 GeV2 | |
| W: | 2.0 — 4.0 GeV | |
| x: | 0.06 — 0.77 | |
| Ebeam: | 10.6041 GeV | |
| Publication: |
T.B. Hayward, C. Dilks, A. Vossen, H. Avakian Observation of Beam Spin Asymmetries in the Process ep→eπ+π-X with CLAS12 //
(submitted to PRL)
|
|
| Q2, [GeV2] | x | M(π+,π−), [GeV] | z | PT, [GeV] | ALUsin (2φh−2φR) | uncertainty | syst. uncert. |
|---|---|---|---|---|---|---|---|
| 1.542 | 0.105 | 0.83 | 0.531 | 0.55 | 0.0183589 | 0.00465242 | 0.00114661451927579 |
| 1.783 | 0.127 | 0.809 | 0.547 | 0.53 | 0.0165393 | 0.0048097 | 0.00117801072893652 |
| 1.953 | 0.143 | 0.794 | 0.557 | 0.526 | 0.0111555 | 0.00492056 | 0.000950595485935785 |
| 2.105 | 0.157 | 0.78 | 0.559 | 0.52 | 0.00761615 | 0.00490442 | 0.00143098696578498 |
| 2.286 | 0.174 | 0.763 | 0.566 | 0.506 | 0.0182973 | 0.00456084 | 0.00143303199000402 |
| 2.471 | 0.191 | 0.749 | 0.571 | 0.5 | 0.0161384 | 0.0048922 | 0.00130434489250387 |
| 2.707 | 0.211 | 0.743 | 0.571 | 0.492 | 0.0170668 | 0.00447472 | 0.00148090293542084 |
| 3.003 | 0.235 | 0.733 | 0.572 | 0.485 | 0.0123978 | 0.00468269 | 0.00131180439262581 |
| 3.307 | 0.261 | 0.716 | 0.571 | 0.468 | 0.0162106 | 0.00500044 | 0.00175347721474318 |
| 3.721 | 0.294 | 0.701 | 0.569 | 0.46 | 0.00824876 | 0.00473665 | 0.0012183965221843 |
| 4.337 | 0.342 | 0.679 | 0.565 | 0.44 | 0.0106562 | 0.00486388 | 0.00157587756640895 |
| 5.658 | 0.44 | 0.63 | 0.547 | 0.408 | 0.00397832 | 0.00499937 | 0.00128465617806676 |
Measurement comment:
Experiment comment:
Process: ep→eπ+π-X
Data tables have the following columns:
- mean Q2
- mean x
- mean Mh, the dihadron invariant mass
- mean z, of the pion pair
- mean PT, more commonly written Ph⊥, is the component of the total dihadron momentum, transverse to q
- ALU amplitude, for a particular modulation
- statistical uncertainty
- systematic uncertainty
For each of the 7 asymmetry modulations, there are 4 tables, one for each binning scheme: (1) binned by x, (2) binned by Mh, (3) binned by z and Mh, and (4) binned by PT and Mh.